General industrial tubing (Urethane)
Flexibility | ||
---|---|---|
Soft | Hard | |
U5 - U2 - U1 | ||
Low | High | |
Pressure resistance |
[For general pneumatic] Urethane tube U2
Fluid used | Air |
Water |
---|---|---|
Operating temperature limit |
-40℃~ +80℃ | 0℃~ +50℃ |
Maximum working pressure |
Millimeter size 0.8MPa Inch size 0.6MPa |
Millimeter size 0.6MPa Inch size 0.4MPa |
Most suitable for general air pressure piping usage.
Well balanced between flexibility and pressure-resistant performance, and high workability.
Ether polyurethane resin is used to prevent degradation by water or mold under high temperature and high humidity.
Coil processing and welding can be performed on request.
Applicable fittings / related products
[For general pneumatic] Urethane tube U1 (high pressure type)
Fluid used | Air |
Water |
---|---|---|
Operating temperature limit |
-40℃~ +80℃ | 0℃~ +50℃ |
Maximum working pressure |
1.2MPa | 0.9MPa |
Usable in higher air-pressure range than U2 tubing.
Ether polyurethane resin is used to prevent degradation by water or mold under
high temperature and high humidity.
Coil processing and welding can be performed on request.
Applicable fittings / related products
[For general pneumatic] Urethane tube U5 (super flexible)
Fluid used | Air |
---|---|
Operating temperature limit |
-40℃~ +80℃ |
Maximum working pressure |
0.4MPa |
The lowest bending stress among Nitta's polyurethane tubes ensures high workability.
Ether polyurethane resin is used to prevent degradation by water or mold under
high temperature and high humidity.
Usable for barb fittings (bamboo-shoot fittings).
Applicable fittings / related products
Urethane coil processed tube UC/USC/UMC
Fluid used | Air |
---|---|
Operating temperature limit |
-40℃~ +80℃ |
Maximum working pressure |
0.8MPa |
Suitable for elastic piping due to coil processing.
When it shrinks, fit into compactly because it has restorability.
Applicable fittings / related products
Urethane multi-line tube UML
Fluid used | Air |
---|---|
Operating temperature limit |
-40℃~ +80℃ |
Maximum working pressure |
0.9MPa |
Multiple Polyurethane tubes of type U2 are welded together.
Contribute to reduce space or improve high workability.